We are here for you if you have any questions:  +49 3385 53710 | info@askania.de

Zeiss SKU: 491239-0020-000

ZEISS Axiovert 7 NMI – Complete System for Inclusion Analysis

Sale price €55.166,00 Regular price €61.296,00
zzgl. 19% MwSt.

Beratung zu diesem Produkt anfordern

Mit dem Absenden Ihrer Anfrage stimmen Sie der Verarbeitung Ihrer Daten zur Bearbeitung Ihrer Anfrage zu. Weitere Informationen finden Sie in unserer Datenschutzerklärung .

Shipping & Delivery

Delivery is available within Germany.

The applicable delivery time will be displayed during the order process (checkout).

Shipping costs will be clearly shown in the shopping cart.

Payment options

You have the choice between payment via PayPal or advance payment (bank transfer). Existing customers have the option to purchase on account. Your payment information will be stored encrypted.

Description

ZEISS Axiovert 7 NMI – Complete system for non-metallic inclusion (NMI) analysis according to standard

The ZEISS Axiovert 7 NMI complete system is a fully pre-configured, standard-compliant microscope system for the analysis of non-metallic inclusions (NMI) in steels and metallic materials.
This complete package meets the technical requirements of common standards (DIN, ISO, ASTM) and is specially designed for metallurgical testing centers, QA laboratories and accredited material laboratories.

At its core is the inverted microscope Axiovert 7 AL, combined with
– HD-capable reflected light optics,
– objective standard configuration (EC Epiplan 5x & 10x),
– Axiocam 705 color R2 high-performance camera,
– motorized scanning stage,
– powerful workstation,
– ZEN core software with Non-Metallic Inclusion Analysis Tool.

This allows you to automate NMI processes, obtain reproducible, documented results and create reports in compliance with standards – completely digitally, quickly and with clearly structured workflows.


Main features

– Complete system specially designed for NMI according to DIN/ISO/ASTM
– Inverted Axiovert 7 AL microscope with HD-LED reflected light (10 W)
– Coded 6-fold HD DIC M27 objective turret
– Axiocam 705 color R2 for high-resolution, noise-free material images
– EC Epiplan objectives 5x & 10x for standard-compliant inclusion analysis
– Motorized XY scanning stage with joystick
– High-performance workstation (Intel i7 / 64 GB RAM / RTX A4000 / 8 TB storage)
– ZEN core 3.12 including Non-Metallic Inclusion Analysis module
– Complete accessory set for steel & sample holder included
– Pre-configured – ideal for accredited material testing laboratories


Ideal for

– Metallurgical laboratories & steel analysis
– QA departments in industrial production
– Material testing according to standard (DIN 50602, ISO 4967, ASTM E45)
– Automated inclusion analysis (A-, B-, C-, D-types)
– Documentation, evaluation & reporting
– Research & development in materials engineering
– Accredited testing laboratories with standard-bound requirements

Downloads

Contact

Do you have any questions?

Please do not hesitate to contact us if you have any questions.
You can reach us by phone at +49 3385 5371 0 or by email at info@askania.de.

Zeiss

Complete system for standard-compliant NMI inclusion analysis with camera & workstation

Microscope Stand Axiovert 7 AL

– 6-position HD DIC M27 nosepiece, coded, slider receptacle 6x20 mm
– 6-position reflector turret, coded for P&C modules
– Receptacle for analyzer slider 12x35 mm
– Reflected light illumination HD, white light LED 10 W (> 60,000 h)
– Receptacles for field, aperture, polarization, & filter sliders
– Interface for HAL 100
– Motorized focus drive, resolution 78 nm
– Focus travel 13 mm, adjustable focus stop
– Release for ZEISS Axiocam
– ECO mode & Light Manager
– Parfocality Manager
– USB 2.0 Type-B PC interface
– Photo intermediate tube H=50 mm, left
– Mirror slider 100% for phototube
– External power supply 24 V DC / 5 A
– Country-specific power cable
– Dust protection set

Stand Accessories

– Filter slider A 14x40 mm, 3-position for Ø 25 mm filters
– Aperture slider A 14x40 mm with aperture/field diaphragm
– Aperture slider A 14x40 mm with aperture diaphragm
– Reflector module brightfield ACR P&C
– Illumination adapter A, achromatic
– Power cable NAG
– Converter CAN–USB Rev. 2

Stages & Accessories

– Motorized scanning stage 130x85 mm, P; CAN
– Insert frame for steel sample holder
– Universal holder frame K

Tube & Optical Accessories

– Binocular tube 45°/23
– Camera adapter 60N-C 2/3" 0.63x, rotatable ± 2°

Eyepieces

– Eyepiece PL 10x/23 Br. foc.
– Eyecup

Objectives (standard-compliant NMI basic optics)

– EC Epiplan 5x/0.13 M27
– EC Epiplan 10x/0.25 M27

Control Devices

– Joystick XY; CAN

Measuring and Counting Components

– Stage micrometer for reflected light 5 + 100/100y

Image Processing – Axiocam 705 color R2

– 5 Megapixel CMOS Global Shutter color camera
– Resolution 2560 × 1920 pixels
– Global shutter for distortion-free motion documentation
– High dynamic range for high-contrast material images
– Optimized for reflected light material analysis
– USB 3.0 SuperSpeed connection
– Low-noise readout, ideal for standard evaluations
– Compatible with ZEN core & NMI module

Workstation & Monitor

– HP Z2 G9 Workstation
– Intel Core i7-12700K
– 64 GB DDR5 RAM (2x32 GB)
– NVIDIA RTX A4000 16 GB
– 8 TB SATA HDD (additional)
– HP Series 7 Pro 724pn monitor, 24"

Software

– ZEN core 3.12
– ZEN Toolkit Motorized Acquisition
– ZEN Module Non-Metallic Inclusion Analysis (NMI)

Supported Standards

✔ ASTM E45
✔ ISO 4967
✔ JIS G0555
✔ GB/T 10561
✔ EN 10247
✔ SEP 1571
✔ DIN 50602