{"product_id":"zeiss-axiovert-7-komplettsystem-fur-die-nichtmetallische-einschlussanalyse-nmi","title":"ZEISS Axiovert 7 NMI – Complete System for Inclusion Analysis","description":"\u003ch3 data-start=\"389\" data-end=\"493\"\u003e\u003cspan style=\"color: rgb(36, 47, 128);\"\u003e\u003cstrong data-start=\"393\" data-end=\"493\"\u003eZEISS Axiovert 7 NMI – Complete system for non-metallic inclusion (NMI) analysis according to standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"495\" data-end=\"906\"\u003eThe \u003cstrong data-start=\"499\" data-end=\"538\"\u003eZEISS Axiovert 7 NMI complete system\u003c\/strong\u003e is a fully pre-configured, standard-compliant microscope system for the \u003cstrong data-start=\"616\" data-end=\"663\"\u003eanalysis of non-metallic inclusions (NMI)\u003c\/strong\u003e in steels and metallic materials.\u003cbr data-start=\"704\" data-end=\"707\"\u003eThis complete package meets the technical requirements of common standards (DIN, ISO, ASTM) and is specially designed for metallurgical testing centers, QA laboratories and accredited material laboratories.\u003c\/p\u003e\n\u003cp data-start=\"908\" data-end=\"1252\"\u003eAt its core is the \u003cstrong data-start=\"933\" data-end=\"969\"\u003einverted microscope Axiovert 7 AL\u003c\/strong\u003e, combined with\u003cbr data-start=\"985\" data-end=\"988\"\u003e– HD-capable reflected light optics,\u003cbr data-start=\"1015\" data-end=\"1018\"\u003e– objective standard configuration (EC Epiplan 5x \u0026amp; 10x),\u003cbr data-start=\"1071\" data-end=\"1074\"\u003e– Axiocam 705 color R2 high-performance camera,\u003cbr data-start=\"1117\" data-end=\"1120\"\u003e– motorized scanning stage,\u003cbr data-start=\"1150\" data-end=\"1153\"\u003e– powerful workstation,\u003cbr data-start=\"1184\" data-end=\"1187\"\u003e– ZEN core software with \u003cstrong data-start=\"1211\" data-end=\"1251\"\u003eNon-Metallic Inclusion Analysis Tool\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1254\" data-end=\"1453\"\u003eThis allows you to automate NMI processes, obtain reproducible, documented results and create reports in compliance with standards – completely digitally, quickly and with clearly structured workflows.\u003c\/p\u003e\n\u003chr data-start=\"1455\" data-end=\"1458\"\u003e\n\u003ch4\u003e\u003cstrong data-start=\"1465\" data-end=\"1482\"\u003eMain features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"1483\" data-end=\"2128\"\u003e– Complete system specially designed for NMI according to DIN\/ISO\/ASTM\u003cbr data-start=\"1544\" data-end=\"1547\"\u003e– Inverted Axiovert 7 AL microscope with HD-LED reflected light (10 W)\u003cbr data-start=\"1608\" data-end=\"1611\"\u003e– Coded 6-fold HD DIC M27 objective turret\u003cbr data-start=\"1657\" data-end=\"1660\"\u003e– Axiocam 705 color R2 for high-resolution, noise-free material images\u003cbr data-start=\"1732\" data-end=\"1735\"\u003e– EC Epiplan objectives 5x \u0026amp; 10x for standard-compliant inclusion analysis\u003cbr data-start=\"1801\" data-end=\"1804\"\u003e– Motorized XY scanning stage with joystick\u003cbr data-start=\"1849\" data-end=\"1852\"\u003e– High-performance workstation (Intel i7 \/ 64 GB RAM \/ RTX A4000 \/ 8 TB storage)\u003cbr data-start=\"1930\" data-end=\"1933\"\u003e– ZEN core 3.12 including \u003cstrong data-start=\"1961\" data-end=\"1996\"\u003eNon-Metallic Inclusion Analysis\u003c\/strong\u003e module\u003cbr data-start=\"1996\" data-end=\"1999\"\u003e– Complete accessory set for steel \u0026amp; sample holder included\u003cbr data-start=\"2061\" data-end=\"2064\"\u003e– Pre-configured – ideal for accredited material testing laboratories\u003c\/p\u003e\n\u003chr data-start=\"2130\" data-end=\"2133\"\u003e\n\u003ch4 data-start=\"2135\" data-end=\"2154\"\u003e\u003cstrong data-start=\"2141\" data-end=\"2154\"\u003eIdeal for\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"2155\" data-end=\"2524\"\u003e– Metallurgical laboratories \u0026amp; steel analysis\u003cbr data-start=\"2193\" data-end=\"2196\"\u003e– QA departments in industrial production\u003cbr data-start=\"2244\" data-end=\"2247\"\u003e– Material testing according to standard (DIN 50602, ISO 4967, ASTM E45)\u003cbr data-start=\"2307\" data-end=\"2310\"\u003e– Automated inclusion analysis (A-, B-, C-, D-types)\u003cbr data-start=\"2366\" data-end=\"2369\"\u003e– Documentation, evaluation \u0026amp; reporting\u003cbr data-start=\"2408\" data-end=\"2411\"\u003e– Research \u0026amp; development in materials engineering\u003cbr data-start=\"2460\" data-end=\"2463\"\u003e– Accredited testing laboratories with standard-bound requirements\u003c\/p\u003e","brand":"Zeiss","offers":[{"title":"Default Title","offer_id":51715452731733,"sku":"491239-0020-000","price":55166.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2847\/6245\/files\/Axiovert7_mat_Axiocam305_system_rechts_3632.png?v=1761055027","url":"https:\/\/askania.de\/en\/products\/zeiss-axiovert-7-komplettsystem-fur-die-nichtmetallische-einschlussanalyse-nmi","provider":"ASKANIA Mikroskoptechnik","version":"1.0","type":"link"}